Lennox Codes: Make Sure the Chart Matches Your Furnace

On the same Lennox model, in two different years of the manufacturer’s own manual, flame rollout moved from three flashes to four. This is the brand where reading the wrong chart matters most.

Licensed & Insured500+ Jobs Completed4.9★ Rated Technicians
Family relaxing together by a window in a warm, comfortable home

Next Phase Heating is an independent HVAC contractor. We are not an authorized dealer for, or affiliated with, any equipment manufacturer. Brand names are used only to identify the equipment we service. Codes vary by model and model year — the legend on your own furnace is always the last word.

First — which of the four does your Lennox use?

Lennox has run four genuinely different diagnostic systems across its range. They do not translate into each other. Getting this right is the whole job.

A display showing E followed by three numbers

The Signature and Elite lines, and the newest Merit models. There is a push button next to the display: hold it to reach the menu, and the E option recalls the last ten codes. A decimal point blinking once a second is idle and completely normal.

One red light, one to nine flashes

The Merit line. This is the system with three incompatible versions, described below. There is a button on the board that replays the last five faults.

Two lights, described as DS1 and DS2

The older SureLight boards. Codes are combinations — one light slow, the other steady, and so on. Lennox itself warns in capital letters to identify which light is which against the board layout first, because a slow flash on the left and a slow flash on the right mean different things.

One light, flashing twice in a pattern

Some SureLight boards flash a number, pause, flash a second number, then a longer pause. Five then one is a rollout lockout on these. We have only found this table in a single Lennox document, so we would want to see your unit before relying on it.

What the codes mean

Stop, and call someone

These are the codes where the furnace has found flame somewhere it should not be. Lennox’s own remedy for one of them begins with the words shut off gas.

E200

Hard lockout — the rollout circuit is open, or has been open

On the display models this is unambiguous and it is the serious one. The furnace has locked itself out because flame reached where it must not. Leave it off.

E241 · E275

Flame sensed out of sequence, and still present

Lennox’s published remedy for E241 starts with shutting off the gas and checking the valve for a leak. That is the manufacturer’s own instruction, not our caution. E275 is the lockout that follows it.

3, 4 or 5 flashes — depending on your model

On the single-light Merit boards, rollout does not sit at a fixed number

This is the single most important thing on this page. On the ML193UH, five flashes is the rollout switch. On the ML296UHV as documented in 2020 and 2021, three flashes covers rollout or a limit. On the same ML296UHV model in the 2024 manual, rollout moved to four flashes and five is no longer used at all. So a Lennox flashing three, four or five deserves the careful answer until you have matched it to your own furnace.

E204 · E205

The gas valve is miswired, or its control relay has shorted closed

Both are gas valve faults on the control side. Not something to reset past.

Usually you, and usually the filter

Lennox is unusually good here — on the display models it has codes that say restricted airflow in as many words, and even a warning code that fires before anything shuts down.

E311

The furnace has quietly turned its own heat output down to match the air it can move

This is a warning rather than a fault, and the furnace keeps running. Lennox’s remedy is to replace the filter or repair the restriction. It is the earliest warning you will get that a filter needs doing, and almost nobody ever sees it because nobody checks the display when the furnace is working.

E291 · E312

Restricted airflow — the blower cannot move what it needs to

E291 is in heating, E312 in cooling or continuous fan. Filter, then every supply register open, then check nothing is against the return.

E250

The limit switch circuit is open

On the display models this is the limit on its own, with rollout reported separately as E200 — which is a genuine advantage of these boards over most other brands. Treat it as an airflow problem: filter, registers, return.

E370

An interlock switch has been open for two minutes

This is usually the blower door. If someone has had the panel off and not clicked it fully back on, this is the code you get.

E223 · E227

The low pressure switch failed to close, or opened during the trial for ignition

Go outside and look at the white intake and exhaust pipes for nests, snow or debris.

Needs a technician, but it is not an emergency

The display models carry a long list of component codes. These are the ones that come up most in a house.

7 or 8 flashes, single-light models

Lockout — it failed to light, or lost the flame too many times

The furnace has given up rather than kept trying. One reset to let it retry is fair. Two means something needs finding.

6 flashes, single-light models

Pressure switch cycle lockout

It has opened and closed too many times in one cycle. Often venting, sometimes the switch.

9 flashes, single-light models

Line voltage polarity is incorrect

A wiring problem rather than a furnace problem.

1 flash, single-light models

Flame present with the gas valve de-energised

Note that on the Merit single-light boards this serious fault is at one flash, which is the opposite end of the scale from where most people expect to find it.

E105 · E110 to E126

Communication and power supply faults on the connected models

These appear on the Signature and Elite units that talk to a communicating thermostat. They are usually wiring or a board, not the burner.

E150 · E151

Refrigerant leak detection on the newest models

The 2024 and later units carry sensors for the new refrigerants. This is the system reporting a sensor or a detection event, and it is a call rather than a wait.

Five ways a Lennox code gets read wrong

There is no error code for a cracked heat exchanger

It is the most searched question about furnaces and one of the most misused in a sales conversation, so plainly: no Lennox control board detects a cracked heat exchanger. Neither does any other manufacturer’s board. The code does not exist. What a board reports is that the rollout circuit opened, or that the limit keeps tripping, and both can be downstream signs of an exchanger that has failed. The crack itself is found by inspection, with a camera and a combustion analyser, by someone who has opened the furnace up. If a replacement quote arrives on the strength of a code alone, get a second number before you spend anything.

Three, four or five flashes on a Merit?

That is the one worth having looked at rather than guessed. Book it and tell us the model number off the door.

Book a Furnace Diagnostic

60 seconds online · or call (206) 486-6373

How it works when you book

Our service areas

We run out of Covington and cover the greater Puget Sound area.

King County

Covington, Kent, Renton, Maple Valley, Auburn, Federal Way, Des Moines, Enumclaw, Bellevue, Issaquah, Sammamish, Bothell

Pierce County

Tacoma, Puyallup, Lakewood, Sumner, Bonney Lake

Snohomish County

Lynnwood, Everett

Not on the list? We cover the greater Puget Sound area around our Covington base. Book it and a technician confirms within 1 business hour.

Why homeowners hand it to us

Book a Furnace Diagnostic

Quick answers

Why does my Lennox chart not match the one I found online?

Because Lennox runs four different diagnostic systems and has revised at least one of them within the same model name. A chart written for a Signature model with a display tells you nothing useful about a Merit with a single blinking light, and a chart for a 2021 Merit can put a safety fault at a different flash count than the 2024 version of the same furnace. Match the model number on the door, not the brand.

I have the Lennox extended warranty. Does that change anything?

Yes, and we would rather tell you now than after we have been out. Lennox’s ordinary warranty is open — their own guidance says homeowners can work with any licensed installer. But the separate extended coverage they sell is different: their terms say the owner must use a participating Lennox dealer, and that Lennox has no liability under it if you do not. We are not a Lennox dealer. So if you bought that extended plan, the repair should go through a dealer to be covered, and it is worth checking your paperwork before booking anyone. If you only have the standard warranty, none of this applies and we are happy to help.

Where do I find which model I actually have?

On the rating plate inside the furnace door, and usually on a sticker on the outside of the cabinet too. Write the whole string down — the difference between ML193UH and ML296UHV is exactly the difference this page is about.

How do I get the stored codes out of a Merit board?

There is a push button on the control. Press and release it and it flashes the last five faults, most recent first. Holding it for more than five seconds clears the history, so be careful not to hold it while you are trying to read it.

Can you work on a Lennox at all if you are not a Lennox dealer?

Yes. Lennox’s own consumer guidance says homeowners have the option to work with any licensed professional installer, and their standard warranty is written that way. The only carve-out is the extended plan described above.

Tell us the model number as well as the code.

Book online in about a minute. On a Lennox the model number is what makes the code mean anything, so put both in the notes.

Book a Furnace Diagnostic

60 seconds online · or call (206) 486-6373

More from our site

Furnace short cyclingFurnace will not startNot sure about a quote?

Furnace repair cost · Flame sensor cost · All troubleshooting guides · Fix it or replace it? · Emergency furnace repair

Book Same-Day Visit Call Now