The light is a flag, not a code

Daikin Codes Live in the Remote, Not in the Blinking

Plenty of articles tell you to count Daikin blink patterns. That is not how these work. The indoor lamp only says a fault exists — you retrieve the actual code with the handset.

Licensed & Insured500+ Jobs Completed4.9★ Rated Technicians
White ductless wall unit installed on a wood-panelled wall with the line cover in place

Next Phase Heating is an independent HVAC contractor. We are not an authorized dealer for, or affiliated with, any equipment manufacturer. Brand names are used only to identify the equipment we service. Codes vary by model and model year — the legend on your own furnace is always the last word.

First — how to get the code out

There are two methods and you will need the second one more often than Daikin’s own instructions imply, because not every code appears in the scrolling list.

Method one: scroll and listen for the long beep

Hold the timer cancel button for five seconds. Two zeros flash on the temperature display. Press timer cancel repeatedly to step through the list. A short beep or two short beeps means keep going. A long beep means you have landed on your code.

Method two: search the two digits

Press temperature up, temperature down and mode at the same time. The left character blinks — step it with the arrows until you hear two beeps. Press mode, then do the same on the right character until you get a long beep. Daikin says outright that not all codes appear in method one, and that this is what you use when you cannot find yours.

Some handsets just show it

On certain remotes, holding timer cancel for five seconds puts the code straight onto the display with a long beep and no scrolling at all. If yours does this, you are done.

A green light on the board inside is not a fault

There is a small green indicator on the control board that blinks to show the processor is alive. It gets reported as a fault code regularly. It is the opposite.

What the codes mean

Refrigerant and electrical faults — not a homeowner job

Nothing on a Daikin carries a do-not-restart warning the way one Mitsubishi code does. But these are the ones where continuing to run it is doing damage rather than testing a theory.

U0

Refrigerant shortage

Daikin arrives at this three different ways — current against compressor speed, discharge pipe temperature, and the difference between suction and discharge. It is not automatically a leak; a faulty sensor or board can produce it. But it is a sealed-system diagnosis and opening that circuit legally requires EPA certification. Running a system that is genuinely short of refrigerant is hard on the compressor, so this is not one to live with.

F3 · F6

Discharge pipe temperature control, or high pressure in cooling

Both mean the system is running far outside where it should be. F6 is worth one outdoor check first — a coil packed with cottonwood or a unit boxed in by a fence will cause it. Beyond that it is refrigerant side.

E5 · E6 · E7

Compressor overload, compressor lock, or the outdoor fan locked

The compressor is drawing too much, has stopped turning, or the fan that cools it has stopped. Repeatedly resetting past any of these is the fastest way to turn a repair into a replacement.

Genuinely worth doing yourself first

One Daikin code is, more often than not, a filter.

A5

Freeze-up protection or heating peak-cut — the unit is protecting itself

Daikin’s own list of causes starts with short-circuited air and a clogged indoor filter, then dust on the indoor coil. In a house, it is usually the filter. Open the front flap, lift out the two mesh screens, wash them, let them dry properly and put them back. Also check nothing is blowing straight back into the unit — furniture, a curtain, or a shelf too close.

L3 · L4

The electrical box or the heat sink in the outdoor unit is getting too hot

Airflow around the outdoor unit. Leaves banked up against it, a shrub that has grown in, snow drifted around the base, or something stored in front of it.

U2

Low or high voltage detected

Worth checking the breaker before assuming the unit is at fault. Note how close this looks to U0 — they are one character apart and completely unrelated.

Needs a technician, but it is not an emergency

Sensors and boards, mostly.

U4

The indoor and outdoor units have stopped talking

Check the outdoor unit has power first. On multi-zone systems this code can mean the link to a branch box rather than to the outdoor unit, and communication with the outdoor unit is reported differently — which is one of several reasons a multi-zone chart is not the same as a single-zone one.

A1

Indoor control board fault

The board has found a problem with itself.

A6

Indoor fan motor

Worth knowing this presents almost identically to A5 from the sofa — the unit is not cooling properly — but A5 is a filter and A6 is a motor.

C4 · C9

Indoor coil thermistor, or room temperature thermistor

Small sensors, small parts.

E1

Outdoor control board fault

The outdoor equivalent of A1.

E8 · L5

Input overcurrent, or output overcurrent

The system is drawing more than it should. Usually points back at the compressor or the inverter.

EA

Four-way valve fault

The valve that flips the system between heating and cooling. A classic symptom is a heat pump that will do one and not the other.

H0 · H6 · H8 · H9 · J3 · J6 · P4

Sensors around the compressor and the outdoor coil

A cluster of thermistor and sensor faults. Individually small parts. H8 means different things depending on the capacity of your unit, which is one to leave to whoever has the model number in front of them.

Four ways a Daikin code gets read wrong

Anything that involves refrigerant is not a do-it-yourself job, and that is federal law rather than our opinion

A good share of Daikin codes point at the sealed system, and U0 in particular is the one people most want to solve themselves after reading that it just needs a top-up. It does not just need a top-up. Refrigerant does not get used up, so a system that is short of it has lost it somewhere, and adding more without finding where is money poured into the ground. Opening a refrigerant circuit also legally requires EPA certification. What you genuinely can do is wash the filters, clear the outdoor coil, and make sure nothing has grown or drifted around the outdoor unit — and between them those cover a real share of the calls we take.

Got the long beep on a code?

Book it and put the two characters in the notes. On a Daikin the code narrows it down a long way before we arrive.

Book a Mini Split Diagnostic

60 seconds online · or call (206) 486-6373

How it works when you book

Our service areas

We run out of Covington and cover the greater Puget Sound area.

King County

Covington, Kent, Renton, Maple Valley, Auburn, Federal Way, Des Moines, Enumclaw, Bellevue, Issaquah, Sammamish, Bothell

Pierce County

Tacoma, Puyallup, Lakewood, Sumner, Bonney Lake

Snohomish County

Lynnwood, Everett

Not on the list? We cover the greater Puget Sound area around our Covington base. Book it and a technician confirms within 1 business hour.

Why homeowners hand it to us

Book a Mini Split Diagnostic

Quick answers

My unit shows a code but it is still running. Do I have to do anything?

Daikin says in its own literature that the system keeps operating even with a code showing, and that you should still get it checked. So there is usually no emergency. The exceptions are the compressor codes, where continuing to run it is what causes the damage rather than the original fault.

Where are the filters and how often should they be done?

Behind the flap on the front of the indoor unit. Lift the flap, slide the two mesh screens out, wash them in warm water, let them dry completely before they go back. Every couple of months in a normal house, more often with pets. It is the single highest-value thing you can do for a ductless system and it prevents the code that brings us out most.

What is the difference between U0 and U2?

Everything, despite them looking almost identical. U0 is refrigerant shortage and points at the sealed system. U2 is a voltage problem and points at the electrical supply. If you are reading a code off a small display in a dim room it is worth confirming which one you have before anyone starts quoting.

Do you work on Daikin if we did not buy it from you?

Yes. Daikin’s warranty asks for correct installation to code by a licensed contractor rather than a particular dealer. The one exclusion worth knowing about is equipment bought by a consumer over the internet, which Daikin treats differently.

Is a Daikin the same as a Goodman?

Same parent company, and Goodman furnaces and Daikin ductless are sold by the same organisation in the US. They are not the same equipment and they do not share a diagnostic system, so a Goodman furnace chart tells you nothing about a Daikin wall unit.

Tell us the code and we will know where to start.

Book online in about a minute. Put the two characters in the notes, and say whether the unit is still running.

Book a Mini Split Diagnostic

60 seconds online · or call (206) 486-6373

More from our site

Mini split not workingMini split blinking lightNot sure about a quote?

Mini split repair cost · Mini split services · All troubleshooting guides · Emergency mini split repair

Book Same-Day Visit Call Now